02.01 Unboxing and Parts Check
Open manual menu
2.1 Unpack and Check the Components
On a clean, dry work surface, check each item against the order and packing list. The sensors are preinstalled on the gloves and do not need to be removed by the user.
Delivery Checklist
| Component | Standard Edition | Haptic Feedback Edition | What to Check |
|---|---|---|---|
| Left and right gloves | 1 each | 1 each | Size, left/right designation, labels, and appearance |
| Wireless receiver | 1 | 2 | Matches the project channel records |
| Mount or Tracker base | As specified in the order | Model, quantity, and fasteners | |
| Button extension module | Optional, 1 for each hand | Check only if included in the order | |
| Glove storage case | 1 | 1 | Zipper operates properly; no visible damage |




Inspection Procedure
- Verify the degrees of freedom, Standard Edition or Haptic Feedback Edition, size, and quantity specified in the order.
- Confirm that the left and right gloves and receivers belong to the same project. Do not mix equipment from different projects.
- Inspect the fabric, wires, data box, connectors, and external modules for moisture, cracks, damage, exposed conductors, or unusual odors.
- Check the mounts, bases, and button extension modules against the packing list.
- Record the product identifiers, channel group, quantities, and any issues in the asset register.
If You Find an Issue
Do not power on or charge the equipment if any components are missing or mismatched, or if you find moisture, damage, exposed conductors, or an unusual odor. Isolate the equipment set and contact the project owner.
Next Step
After the inspection is complete, proceed to 2.2 Install the Mount or Tracker Base.